Madico's SafetyShield® blast mitigation films are the most reliable defense against the risks posed by explosive incidents. These high-performance window security films are engineered to keep shattered glass intact, significantly reducing the risk of injury and property damage. Extensively tested to exceed both U.S. and international safety standards, our films and patented anchoring systems provide passive, round-the-clock protection. Trusted for over a century, Madico continues to innovate and lead the industry with solutions that combine cost-effectiveness and superior performance.
Discover the key benefits of Madico's SafetyShield® blast mitigation films, designed to ensure safety and security in educational and commercial settings.
WATCH: SafetyShield Threat Compilation
Our films keep shattered glass together, reducing the risk of injury from flying shards.
SafetyShield® films exceed GSA and ISO criteria, offering superior performance against high-explosive charges.
Our unique anchoring systems provide continuous, passive protection and activate instantly during a threat.
SafetyShield® films are an economical solution to mitigate the risks of explosions and natural disasters.
With over 120 years of innovation, Madico is a trusted leader in safety and security solutions.
Our films are manufactured in the USA, ensuring high quality and availability.
There are four different patented and proprietary Anchoring Restraint System solutions available – each with its own level of performance. Our highly-trained Premier Partners will work with you to select the appropriate Anchoring Restraint System, in conjunction with the application of our safety film, to meet your specific criteria and threat concern.
FrameGardTMThe FrameGard Anchoring System when used in conjunction with SafetyShield film has been specifically engineered to keep treated glass within the frame when an incident has occurred. It is a “mechanical” attachment system that clamps the filmed glass to the window frame. This system improves and extends the principle of edge battening by incorporating a specific movement zone (patent applies), which allows the film to move under the applied load without putting excessive force on the fixings and frame. The benefit of FrameGard is that it allows engineers and installers to precisely determine torque settings for each individual installation, creating a truly custom solution.
GullWing®
The GullWing Anchoring System, when combined with Madico SafetyShield window film, is designed to absorb and disperse the energy that the filmed glass is subjected to and transfer the reduced load over the entire glazed opening. By absorbing and distributing the load, the system is designed to retain the filmed glass in the opening and thus reduce the probability of glass fragments and debris from entering the room.
Wet Glaze
In the event of glass breakage, the Wet Glaze Anchoring System, when combined with SafetyShield window film, is designed to absorb and disburse the energy that the filmed glass is subjected to and transfer the reduced load over the entire glazed opening. By absorbing and distributing the load, the system is designed to retain the filmed glass in the opening and thus reduce the probability of glass fragments and debris from entering the room.
The Wet Glaze system is economically viable in retrofit applications and is built around a triangular sealant joint connecting the film to the supporting framing members. To achieve acceptable performance, a very high-performance sealant must be used. We recommend Dow Corning® 995 Silicone Structural Adhesive or GE SCS2000 SilPruf™ Sealant.
LifeLine®
The LifeLine Anchoring System is based on a simple principle, “restraint”. This system is one of the most effective ways to mitigate injury and reduce property damage in the event of a catastrophic blast. The LifeLine System works in conjunction with a standard application of SafetyShield film. The system’s energy-absorbing cords slow down and catch the filmed lite of glass, often returning it to the direction in which it came. This straight-forward system has been blast tested up to 10 psi. Due to its somewhat industrial appearance, LifeLine is primarily used in factory or manufacturing applications.
Product specs | |
% Visible Light - Trans. | 88% |
% Visible Light - Reflected External | 9% |
% Visible Light - Reflected Internal | 9% |
% Visible Light - Glare Reduction | 1% |
% Total Solar Energy - Trans. | 75% |
% Total Solar Energy - Reflected External | 7% |
% Total Solar Energy - Absorbed | 18% |
Shading Coefficient (SC) | 0.93 |
Solar Heat Gain Coefficient (SHGC) | 0.81 |
U Factor | 1.05 |
UV Rejection | ≥ 99% |
Emissivity | 0.91 |
Light to Solar Gain | 1.09 |
Total Solar Energy Rejected (TSER) | 20% |
IR Rejection (see PDF for details) | 32% |
Infrared Energy Rejection (IRER) | 23% |
Film Thickness | 0.008" |
Structural Components | 0.007" |
Structure | Single Ply |
Adhesive Type | Acrylic Pressure Sensitive |
Longitudinal Tensile Strength | 28,000 PSI Avg. MD/TD |
Traverse Tensile Strength | 36,000 PSI Avg. MD/TD |
Break Strength | 210 lbs. Per Inch (Width) |
Longitudinal Elongation at Break | 150% |
Traverse Elongation at Break | 100% |
Yield Strength | 14,000 PSI Avg. MD/TD |
Elongation at Yield | 120% |
Peel Strength | 5 to 6 lbs. Per Inch Width |
Product specs | |
% Visible Light - Trans. | 87% |
% Visible Light - Reflected External | 9% |
% Visible Light - Reflected Internal | 10% |
% Visible Light - Glare Reduction | 2% |
% Total Solar Energy - Trans. | 74% |
% Total Solar Energy - Reflected External | 8% |
% Total Solar Energy - Absorbed | 18% |
Shading Coefficient (SC) | 0.92 |
Solar Heat Gain Coefficient (SHGC) | 0.80 |
U Factor | 1.05 |
UV Rejection | ≥ 99% |
Emissivity | 0.90 |
Light to Solar Gain | 1.09 |
Total Solar Energy Rejected (TSER) | 20% |
IR Rejection (see PDF for details) | 34% |
Infrared Energy Rejection (IRER) | 24% |
Film Thickness | 0.0095" |
Structural Components | 0.008" |
Structure | Multi-Ply Laminate |
Adhesive Type | Acrylic Pressure Sensitive |
Longitudinal Tensile Strength | 28,000 PSI Avg. MD/TD |
Traverse Tensile Strength | 36,000 PSI Avg. MD/TD |
Break Strength | 240 lbs. Per Inch (Width) |
Longitudinal Elongation at Break | 150% |
Traverse Elongation at Break | 100% |
Yield Strength | 14,000 PSI Avg. MD/TD |
Elongation at Yield | 120% |
Peel Strength | 5 to 6 lbs. Per Inch Width |
Product specs | |
% Visible Light - Trans. | 85% |
% Visible Light - Reflected External | 10% |
% Visible Light - Reflected Internal | 10% |
% Visible Light - Glare Reduction | 4% |
% Total Solar Energy - Trans. | 71% |
% Total Solar Energy - Reflected External | 8% |
% Total Solar Energy - Absorbed | 21% |
Shading Coefficient (SC) | 0.89 |
Solar Heat Gain Coefficient (SHGC) | 0.78 |
U Factor | 1.04 |
UV Rejection | ≥ 99% |
Emissivity | 0.90 |
Light to Solar Gain | 1.10 |
Total Solar Energy Rejected (TSER) | 22% |
IR Rejection (see PDF for details) | 41% |
Infrared Energy Rejection (IRER) | 27% |
Film Thickness | 0.017" |
Structural Components | 0.015" |
Structure | Multi-Ply Laminate |
Adhesive Type | Acrylic Pressure Sensitive |
Longitudinal Tensile Strength | 28,000 PSI Avg. MD/TD |
Traverse Tensile Strength | 36,000 PSI Avg. MD/TD |
Break Strength | 450 lbs. Per Inch (Width) |
Longitudinal Elongation at Break | 150% |
Traverse Elongation at Break | 100% |
Yield Strength | 14,000 PSI Avg. MD/TD |
Elongation at Yield | 120% |
Peel Strength | 5 to 6 lbs. Per Inch Width |
Product specs | |
% Visible Light - Trans. | 44% |
% Visible Light - Reflected External | 28% |
% Visible Light - Reflected Internal | 27% |
% Visible Light - Glare Reduction | 51% |
% Total Solar Energy - Trans. | 31% |
% Total Solar Energy - Reflected External | 24% |
% Total Solar Energy - Absorbed | 45% |
Shading Coefficient (SC) | 0.51 |
Solar Heat Gain Coefficient (SHGC) | 0.44 |
U Factor | 0.95 |
UV Rejection | ≥ 99% |
Emissivity | 0.70 |
Light to Solar Gain | 0.99 |
Total Solar Energy Rejected (TSER) | 56% |
IR Rejection (see PDF for details) | 83% |
Infrared Energy Rejection (IRER) | 62% |
Film Thickness | 0.010" |
Structural Components | 0.0085" |
Structure | Multi-Ply Laminate |
Adhesive Type | Acrylic Pressure Sensitive |
Longitudinal Tensile Strength | 28,000 PSI Avg. MD/TD |
Traverse Tensile Strength | 36,000 PSI Avg. MD/TD |
Break Strength | 240 lbs. Per Inch (Width) |
Longitudinal Elongation at Break | 150% |
Traverse Elongation at Break | 100% |
Yield Strength | 14,000 PSI Avg. MD/TD |
Elongation at Yield | 120% |
Peel Strength | 5 to 6 lbs. Per Inch Width |
Product specs | |
% Visible Light - Trans. | 17% |
% Visible Light - Reflected External | 56% |
% Visible Light - Reflected Internal | 58% |
% Visible Light - Glare Reduction | 81% |
% Total Solar Energy - Trans. | 12% |
% Total Solar Energy - Reflected External | 45% |
% Total Solar Energy - Absorbed | 43% |
Shading Coefficient (SC) | 0.27 |
Solar Heat Gain Coefficient (SHGC) | 0.23 |
U Factor | 0.88 |
UV Rejection | ≥ 99% |
Emissivity | 0.58 |
Light to Solar Gain | 0.74 |
Total Solar Energy Rejected (TSER) | 77% |
IR Rejection (see PDF for details) | 95% |
Infrared Energy Rejection (IRER) | 78% |
Film Thickness | 0.010" |
Structural Components | 0.0085" |
Structure | Multi-Ply Laminate |
Adhesive Type | Acrylic Pressure Sensitive |
Longitudinal Tensile Strength | 28,000 PSI Avg. MD/TD |
Traverse Tensile Strength | 36,000 PSI Avg. MD/TD |
Break Strength | 240 lbs. Per Inch (Width) |
Longitudinal Elongation at Break | 150% |
Traverse Elongation at Break | 100% |
Yield Strength | 14,000 PSI Avg. MD/TD |
Elongation at Yield | 120% |
Peel Strength | 5 to 6 lbs. Per Inch Width |
Product specs | |
% Visible Light - Trans. | 43% |
% Visible Light - Reflected External | 14% |
% Visible Light - Reflected Internal | 17% |
% Visible Light - Glare Reduction | 51% |
% Total Solar Energy - Trans. | 34% |
% Total Solar Energy - Reflected External | 14% |
% Total Solar Energy - Absorbed | 52% |
Shading Coefficient (SC) | 0.57 |
Solar Heat Gain Coefficient (SHGC) | 0.49 |
U Factor | 0.95 |
UV Rejection | ≥ 99% |
Emissivity | 0.71 |
Light to Solar Gain | 0.88 |
Total Solar Energy Rejected (TSER) | 51% |
IR Rejection (see PDF for details) | 76% |
Infrared Energy Rejection (IRER) | 55% |
Film Thickness | 0.010" |
Structural Components | 0.0085" |
Structure | Multi-Ply Laminate |
Adhesive Type | Acrylic Pressure Sensitive |
Longitudinal Tensile Strength | 28,000 PSI Avg. MD/TD |
Traverse Tensile Strength | 36,000 PSI Avg. MD/TD |
Break Strength | 240 lbs. Per Inch (Width) |
Longitudinal Elongation at Break | 150% |
Traverse Elongation at Break | 100% |
Yield Strength | 14,000 PSI Avg. MD/TD |
Elongation at Yield | 120% |
Peel Strength | 5 to 6 lbs. Per Inch Width |
Product specs | |
% Visible Light - Trans. | 36% |
% Visible Light - Reflected External | 15% |
% Visible Light - Reflected Internal | 22% |
% Visible Light - Glare Reduction | 60% |
% Total Solar Energy - Trans. | 28% |
% Total Solar Energy - Reflected External | 15% |
% Total Solar Energy - Absorbed | 57% |
Shading Coefficient (SC) | 0.51 |
Solar Heat Gain Coefficient (SHGC) | 0.45 |
U Factor | 0.96 |
UV Rejection | ≥ 99% |
Emissivity | 0.73 |
Light to Solar Gain | 0.80 |
Total Solar Energy Rejected (TSER) | 55% |
IR Rejection (see PDF for details) | 82% |
Infrared Energy Rejection (IRER) | 59% |
Film Thickness | 0.010" |
Structural Components | 0.0085" |
Structure | Multi-Ply Laminate |
Adhesive Type | Acrylic Pressure Sensitive |
Longitudinal Tensile Strength | 28,000 PSI Avg. MD/TD |
Traverse Tensile Strength | 36,000 PSI Avg. MD/TD |
Break Strength | 240 lbs. Per Inch (Width) |
Longitudinal Elongation at Break | 150% |
Traverse Elongation at Break | 100% |
Yield Strength | 14,000 PSI Avg. MD/TD |
Elongation at Yield | 120% |
Peel Strength | 5 to 6 lbs. Per Inch Width |
Product specs | |
% Visible Light - Trans. | 14% |
% Visible Light - Reflected External | 49% |
% Visible Light - Reflected Internal | 20% |
% Visible Light - Glare Reduction | 85% |
% Total Solar Energy - Trans. | 14% |
% Total Solar Energy - Reflected External | 41% |
% Total Solar Energy - Absorbed | 46% |
Shading Coefficient (SC) | 0.31 |
Solar Heat Gain Coefficient (SHGC) | 0.27 |
U Factor | 0.94 |
UV Rejection | ≥ 99% |
Emissivity | 0.69 |
Light to Solar Gain | 0.52 |
Total Solar Energy Rejected (TSER) | 73% |
IR Rejection (see PDF for details) | 91% |
Infrared Energy Rejection (IRER) | 69% |
Film Thickness | 0.011" |
Structural Components | 0.0095" |
Structure | Multi-Ply Laminate |
Adhesive Type | Acrylic Pressure Sensitive |
Longitudinal Tensile Strength | 28,000 PSI Avg. MD/TD |
Traverse Tensile Strength | 36,000 PSI Avg. MD/TD |
Break Strength | 240 lbs. Per Inch (Width) |
Longitudinal Elongation at Break | 150% |
Traverse Elongation at Break | 100% |
Yield Strength | 14,000 PSI Avg. MD/TD |
Elongation at Yield | 120% |
Peel Strength | 5 to 6 lbs. Per Inch Width |
Product specs | |
% Visible Light - Trans. | 26% |
% Visible Light - Reflected External | 29% |
% Visible Light - Reflected Internal | 15% |
% Visible Light - Glare Reduction | 71% |
% Total Solar Energy - Trans. | 25% |
% Total Solar Energy - Reflected External | 26% |
% Total Solar Energy - Absorbed | 49% |
Shading Coefficient (SC) | 0.45 |
Solar Heat Gain Coefficient (SHGC) | 0.39 |
U Factor | 0.96 |
UV Rejection | ≥ 99% |
Emissivity | 0.72 |
Light to Solar Gain | 0.65 |
Total Solar Energy Rejected (TSER) | 61% |
IR Rejection (see PDF for details) | 82% |
Infrared Energy Rejection (IRER) | 55% |
Film Thickness | 0.011" |
Structural Components | 0.0095" |
Structure | Multi-Ply Laminate |
Adhesive Type | Acrylic Pressure Sensitive |
Longitudinal Tensile Strength | 28,000 PSI Avg. MD/TD |
Traverse Tensile Strength | 36,000 PSI Avg. MD/TD |
Break Strength | 240 lbs. Per Inch (Width) |
Longitudinal Elongation at Break | 150% |
Traverse Elongation at Break | 100% |
Yield Strength | 14,000 PSI Avg. MD/TD |
Elongation at Yield | 120% |
Peel Strength | 5 to 6 lbs. Per Inch Width |
Product specs | |
% Visible Light - Trans. | 65% |
% Visible Light - Reflected External | 26% |
% Visible Light - Reflected Internal | 27% |
% Visible Light - Glare Reduction | 27% |
% Total Solar Energy - Trans. | 43% |
% Total Solar Energy - Reflected External | 30% |
% Total Solar Energy - Absorbed | 27% |
Shading Coefficient (SC) | 0.58 |
Solar Heat Gain Coefficient (SHGC) | 0.51 |
U Factor | 0.94 |
UV Rejection | ≥ 99% |
Emissivity | 0.68 |
Light to Solar Gain | 1.28 |
Total Solar Energy Rejected (TSER) | 49% |
IR Rejection (see PDF for details) | 81% |
Infrared Energy Rejection (IRER) | 56% |
Film Thickness | 0.0105" |
Structural Components | 0.009" |
Structure | Multi-Ply Laminate |
Adhesive Type | Acrylic Pressure Sensitive |
Longitudinal Tensile Strength | 28,000 PSI Avg. MD/TD |
Traverse Tensile Strength | 36,000 PSI Avg. MD/TD |
Break Strength | 240 lbs. Per Inch (Width) |
Longitudinal Elongation at Break | 150% |
Traverse Elongation at Break | 100% |
Yield Strength | 14,000 PSI Avg. MD/TD |
Elongation at Yield | 120% |
Peel Strength | 5 to 6 lbs. Per Inch Width |
The document provides detailed performance measurements of various SafetyShield® films, including their solar energy rejection, UV rejection, and physical properties, demonstrating their effectiveness in glare reduction, infrared energy rejection, and tensile strength.
DownloadMadico's FrameGard Anchoring System, designed for use with SafetyShield window films, ensures treated glass remains securely in place during incidents, offering certified performance in blast mitigation and improved safety by mechanically clamping the filmed glass to the window frame, absorbing energy, and preventing glass shards from causing harm.
DownloadMadico's GullWing Anchoring System, used with SafetyShield window films, absorbs and disperses impact energy across the entire glazed area, retaining glass fragments and preventing debris from entering a room. This system offers certified performance and comes in various sizes to fit different window frames, ensuring optimal safety and security.
DownloadMadico's LifeLine Anchoring System works with SafetyShield film to provide superior protection by absorbing and redirecting blast energy, preventing glass shards from entering buildings. This system is especially effective in industrial settings, offering tested performance up to 10 psi to reduce injury and property damage during catastrophic events.
DownloadMadico's Wet Glaze Anchoring System enhances the performance of SafetyShield window films by absorbing and distributing energy from impacts and blasts, keeping glass fragments contained and reducing the risk of injury and property damage. Ideal for retrofit applications, this system offers a cost-effective solution for enhancing glass safety and security.
Download